Parker CETOP 3 Solenoid Valve
Mounting: NFPA D03 DIN NG6
Max press: P. A. B ports 345bar
Max press: T port 210 bar
Max flow: 80 lpm selected spool configurations only

Parker D1VL Lever Operated Cetop 3
Mounting: NFPA D03/ DIN NG6
Max press: P. A. B ports 345bar
Max press: T port 34 bar

D1VP Oil Operated Cetop 3
Mounting: NFPA D03/ DIN NG6
Max press: P. A. B ports 345bar
Max press: T port 207 bar
Pilot pressure: D1VP – 15.2 Bar (220 PSI) minimum
207 Bar (3000 PSI) maximum

D1VA Air Operated Cetop 3
Mounting: NFPA D03/ DIN NG6
Max press: P. A. B ports 345bar
Max press: T port 34 bar
Pilot pressure: D1VA – 4.1 Bar (60 PSI) minimum
10.2 Bar (150 PSI) maximum

D1VC Cam Operated Cetop 3
Mounting: NFPA D03/ DIN NG6
Max press: P. A. B ports 345bar
Max press: T port 34 bar

Parker CETOP 5 Solenoid Valve
Mounting: CETOP 5 NFPA D05/ DIN NG10
Max press: P.A .B 350bar
Max press: T port 210bar
Max flow: 150 lpm selected spool configurations only